Water expands by roughly one-eleventh of its volume when it freezes, according to Colorado State University Extension, and that is enough force to split buried pipe, crack valve bodies and break sprinkler cases. An in-ground system has to be emptied before the ground freezes hard, and the order of the work matters as much as the method.
Shut off the supply first
Colorado State University Extension starts with the stop-and-waste valve that sits between the water supply and the backflow device. It may be in a basement or crawlspace, or in an underground valve box that the extension says can be about 5 feet deep, which calls for a long valve key. The extension warns against forcing the valve in either direction. Rain Bird, an irrigation manufacturer, also closes the mainline shutoff first in every method it describes.
Protect the backflow preventer
The backflow device is the part most often damaged by air, and Colorado State separates the common types. An atmospheric vacuum breaker can be cleared along with the zone it serves, though the extension notes these devices are not allowed everywhere and points homeowners to their water district or building department to check. A pressure vacuum breaker or a reduced pressure assembly should never have compressed air pushed through it, because the heat can melt its internal rubber seals.
For a pressure vacuum breaker, the extension says to drain the risers on both sides of the device, work the ball valves and test cocks several times, and leave them half open for the winter, since a valve left fully open or fully closed can trap water. For a reduced pressure assembly, the steps include slowly closing the upstream shutoff and opening test cocks 2 and 3, then leaving the isolation ball valves at about 45 degrees. If the backflow device has no blowout fitting on its downstream side, Colorado State says one has to be added before the lines can be blown out. Rain Bird adds insulating valve boxes and backflow preventers once the system is drained.
Three ways to get the water out
- Manual drain valves. Rain Bird says to close the mainline shutoff, open one control valve to relieve pressure on the mainline, then open each manual drain valve slowly, wearing eye protection because the line is pressurized until that relief step is done.
- Automatic drain valves. These spring-loaded valves on heads or pipe empty the line each time the system shuts off, according to Rain Bird, which advises checking for heavy puddling that can mean a drain is stuck open. University of Georgia Extension describes the same valves as closing at 9 to 10 psi and opening when pressure drops below that.
- Compressed-air blowout. Colorado State calls this the only reliable method and says any system with electric valves must be blown out, because water otherwise stays on top of the valve diaphragm. University of Georgia Extension adds that neither automatic nor manual drain valves can empty every component.
Pressure limits for a blowout
Colorado State University Extension gives a compressor range of 40 to 80 psi, with 80 psi as the ceiling for rigid PVC pipe and 50 psi as the ceiling for flexible black polyethylene pipe. It says to set the compressor's regulator to match, since pressure above a nozzle's rating can blow the nozzle off. Rain Bird's homeowner instructions set the regulator at 50 psi and say the air pressure in the lines should not exceed 50 psi.
Both sources say to run one zone at a time. Colorado State recommends two short passes per zone and warns against blowing a zone that is already clear, because air moving through dry pipe builds heat that can damage or melt pipe and fittings. Rain Bird limits each pass to 2 minutes and says to keep one zone open while the compressor is shut off.
The controller
During a blowout the controller opens each zone in turn, and Rain Bird says not to turn it off until the compressor is off; afterward, it says to set the timer to off. Colorado State takes a different view on power: it recommends leaving the controller plugged in all winter, because heat from the transformer limits moisture and corrosion, and running a minimum cycle once a week so the solenoid plungers do not stick.
Why many owners hire it out
A blowout combines a pressurized air tank, a fitting on the backflow device and heads that can eject debris. Rain Bird says anyone without the right compressor, or unsure of the procedure, should have a professional do it, and Colorado State lists eye protection and keeping pets away from the noise among its safety steps. For irrigation repairs, the EPA WaterSense program points homeowners to irrigation professionals certified through a WaterSense labeled program.
The next step is to find the stop-and-waste valve and identify the type of backflow device on the system before the first hard freeze, then decide whether to drain it yourself or book an irrigation contractor while appointments are still open.
This article reports rules, data and expert guidance. It is not legal, tax, insurance or financial advice. Talk to a licensed pro, your tax advisor or your insurer before you act on it.